HPLC comes up often in conversation and rarely with the context attached. Here we lay out the basics in order, then work through the practical considerations.
Last reviewed on 2025-12-21. Where a claim depends on a specific study, the study is described rather than over-claimed.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. A diode array detector records full spectra across a wavelength range, which helps identify co-eluting peaks. Mass spectrometry provides mass-to-charge ratios and can confirm molecular identity at low concentrations. The choice of detector depends on analyte structure, required sensitivity, and whether quantitation or identification is the goal. No single detector works for every compound, and method development often compares responses before selecting one.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Most common for neutral and moderately polar analytes |
| Column particle size | 3–5 µm | Smaller particles improve resolution but raise backpressure |
| Mobile phase pH range | 2–8 | Silica-based columns may degrade outside this range |
| Typical flow rate | 1.0–2.0 mL/min | For analytical columns with 4.6 mm internal diameter |
| Common synonyms | HPLC, LC, high-pressure liquid chromatography | High-performance liquid chromatography is the standard expansion |
Most routine HPLC testing uses reversed-phase columns, where the stationary phase is nonpolar and the mobile phase is a polar mixture such as water with an organic solvent. Analytes partition between the two phases according to polarity, size, and charge. Gradients that change solvent composition over time can separate compounds with broad retention ranges. Isocratic conditions keep solvent composition constant and suit simpler mixtures. The choice of column chemistry, pH, and temperature affects selectivity and peak shape.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. UV detection is widely used because many organic compounds absorb light, but it requires a chromophore. Mass spectrometry provides mass-based identification and high sensitivity for trace analytes. Each detector has trade-offs in selectivity, cost, and compatibility with mobile phases. Quantification typically uses calibration curves prepared from reference standards. Results are reported as concentration, purity, or presence above a limit.
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
In the late 1990s, evidence began accumulating to suggest that some GPCRs are able to signal without G proteins. The ERK2 mitogen-activated protein kinase, a key signal transduction mediator downstream of receptor activation in many pathways, has been shown to be activated in response to cAMP-mediated receptor activation in the slime mold D. discoideum despite the absence of the associated G protein α- and β-subunits. In mammalian cells, the much-studied β2-adrenoceptor has been demonstrated to activate the ERK2 pathway after arrestin-mediated uncoupling of G-protein-mediated signaling. Therefore, it seems likely that some mechanisms previously believed related purely to receptor desensitisation are actually examples of receptors switching their signaling pathway, rather than simply being switched off. In kidney cells, the bradykinin receptor B2 has been shown to interact directly with a protein tyrosine phosphatase. The presence of a tyrosine-phosphorylated ITIM (immunoreceptor tyrosine-based inhibitory motif) sequence in the B2 receptor is necessary to mediate this interaction and subsequently the antiproliferative effect of bradykinin.
Berg did not complete his final step due to the pleas of several fellow investigators, including Robert Pollack, who feared the biohazards associated with the last step. The SV40 was known to cause cancer tumors to develop in mice. Additionally, the E. coli bacterium (although not the strain used by Berg) inhabited the human intestinal tract. For these reasons, the other investigators feared that the final step would create cloned SV40 DNA that might escape into the environment and infect laboratory workers. These workers could then become cancer victims. Concern about this potential biohazard, along with others, caused a group of leading researchers to send a letter to the president of the National Academy of Sciences (NAS). In this letter, they requested that he appoint an ad hoc committee to study the bio-safety ramifications of this new technology. This committee, called the Committee on Recombinant DNA molecules of the National Academy of Science, U.S.A., held in 1974, concluded that an international conference was necessary to resolve the issue and that until that time, scientists should halt experiments involving recombinant DNA technology.
Seven genes encode seven distinct 14-3-3 proteins in most mammals (See Human genes below) and 13–15 genes in many higher plants, though typically in fungi they are present only in pairs. Protists have at least one. Eukaryotes can tolerate the loss of a single 14-3-3 gene if multiple genes are expressed, but deletion of all 14-3-3s (as experimentally determined in yeast) results in death. 14-3-3 proteins are structurally similar to the Tetratrico Peptide Repeat (TPR) superfamily, which generally have 9 or 10 alpha helices, and usually form homo- and/or hetero-dimer interactions along their amino-termini helices. These proteins contain a number of known common modification domains, including regions for divalent cation interaction, phosphorylation & acetylation, and proteolytic cleavage, among others established and predicted. 14-3-3 binds to peptides. There are common recognition motifs for 14-3-3 proteins that contain a phosphorylated serine or threonine residue, although binding to non-phosphorylated ligands has also been reported. This interaction occurs along a so-called binding groove or cleft that is amphipathic in nature. To date, the crystal structures of six classes of these proteins have been resolved and deposited in the public domain.
As anti-angiogenic cancer therapies have achieved widespread use, there has been increased interest in non-invasive monitoring of angiogenesis. One of the most extensively examined targets of angiogenesis is integrin αVβ3. Radiolabeled peptides containing RGD show high affinity and selectivity for integrin αVβ3 and are being investigated as tools to monitor treatment response of tumors via PET imaging. These include 18F-Galacto-RGD, 18F-Fluciclatide-RGD, 18F-RGD-K5, 68Ga-NOTA-RGD, 68Ga-NOTA-PRGD2, 18F-Alfatide, 18F-Alfatide II, and 18F-FPPRGD2. In a meta-analysis of studies using PET/CT in patients with cancer, it was shown that this diagnostic method may be very useful for detecting malignancies and predicting short-term outcomes, although larger-scale studies are needed.
Two additional amino acids are in some species coded for by codons that are usually interpreted as stop codons: In addition to the specific amino acid codes, placeholders are used in cases where chemical or crystallographic analysis of a peptide or protein cannot conclusively determine the identity of a residue. They are also used to summarize conserved protein sequence motifs. The use of single letters to indicate sets of similar residues is similar to the use of abbreviation codes for degenerate bases.
Sources: en.wikipedia.org
Abraham White (March 8, 1908 – February 14, 1980) was a professor of biochemistry who made several important discoveries in his field during the middle of the 20th century and helped write a foundational textbook, Principles of Biochemistry, which was published in 1954. The book went through six editions before its authors retired. White was born in Cleveland, Ohio, to Morris and Lena White. His siblings were Essie and Julius ("Jay"). When he was about one year old, his family moved to Lafayette, Colorado, and then later to Denver. White earned his bachelor's and master's degrees at the University of Colorado and a Ph.D. degree in Physiological Chemistry at the University of Michigan in the laboratory of Howard B. Lewis. This was followed by a postdoctoral fellowship at the Yale School of Medicine with Hubert Bradford Vickery at the Connecticut Agricultural Experiment Station.
Non-specific active immunotherapy: generating a general immune system response using cytokines and other cell signaling molecules. Specific active immunotherapy: the generation of cell-mediated and antibody immune responses focused on specific antigens expressed by the cancer cells, typically using a vaccine platform. Active immunotherapies fall under the category of activation immunotherapies, which is a subset of immunotherapies that activate the immune system as opposed immunotherapies that suppress the immune system. Non-specific active immunotherapy is administered with the overall goal of generally eliminating malignant pathogens or cells from the host system. This treatment stimulates the immune system in a general sense, rather than specifically targeting a cell type e.g. cancer cells. Non-specific approaches aim to create a robust immune response that would lead to the eventual killing of malignant cells through immunomodulators such as cytokines.
While the Arrhenius concept is useful for describing many reactions, it is also quite limited in its scope. In 1923, chemists Johannes Nicolaus Brønsted and Thomas Martin Lowry independently recognized that acid–base reactions involve the transfer of a proton. A Brønsted–Lowry acid (or simply Brønsted acid) is a species that donates a proton to a Brønsted–Lowry base. Brønsted–Lowry acid–base theory has several advantages over Arrhenius theory. Consider the following reactions of acetic acid (CH3COOH), the organic acid that gives vinegar its characteristic taste:
Agonists PACAP-38 (endogenous peptide agonist, full length version) - also activates other receptors VIP, GPR55 and MRGPRX2 and the Secretin receptor. PACAP-27 (endogenous peptide agonist, shorter fragment which retains activity) Antagonists PACAP(6-38) - N-terminal truncated version of the endogenous peptide agonist which acts as a potent PAC1 antagonist BAY 2686013 PA-915 "VIP and PACAP Receptors: PAC1". IUPHAR Database of Receptors and Ion Channels. International Union of Basic and Clinical Pharmacology. Human ADCYAP1R1 genome location and ADCYAP1R1 gene details page in the UCSC Genome Browser. This article incorporates text from the United States National Library of Medicine, which is in the public domain.
Sources: en.wikipedia.org
Leukolike vectors are a type of nanoparticles made of nanoporous silicon encapsulated by extracted native leukocyte membranes. These particles were among the first artificial white blood cells to be studied as a proof of concept of using cellular membranes to prolong circulation of nanoparticles throughout the blood. Studies have shown that leukolike vectors have a specific advantage in chemotherapy drug delivery to cancer. This is because leukolike vectors specifically have the potential to bind to tumor endothelium.
ACS Publications is the publishing division of the ACS. It is a nonprofit academic publisher of scientific journals covering various fields of chemistry and related sciences. As of 2026, ACS Publications published the following peer-reviewed journals: In addition to academic journals, ACS Publications also publishes Chemical & Engineering News, a weekly trade magazine covering news in the chemical profession, inChemistry, a magazine for undergraduate students, and ChemMatters, a magazine for high school students and teachers. ACS also created ChemRxiv, which is an open access preprint repository for the chemical sciences, co-owned, and collaboratively managed by the American Chemical Society (ACS), German Chemical Society (GDCh), Royal Society of Chemistry (RSC), the chemistry community, other societies, funders, and non-profits; open for submissions and available for all readers at ChemRxiv.
Acceptance sampling procedures became common during World War II. Sampling plans, such as MIL-STD-105, were developed by Harold F. Dodge and others and became frequently used as standards. More recently, quality assurance broadened the scope beyond final inspection to include all aspects of manufacturing. Broader quality management systems include methodologies such as statistical process control, HACCP, six sigma, and ISO 9000. Some use of acceptance sampling still remains.
Alexander Bont is a character appearing in American comic books published by Marvel Comics. Created by writer Brian Michael Bendis and artist Alex Maleev, the character first appeared in Daredevil vol. 2 #66 (December 2004). Bont is one of the first villains encountered by the superhero Matt Murdock / Daredevil. Once the Kingpin of New York's criminal underworld prior to Wilson Fisk's ascent, Bont also employed the man responsible for murdering Jack Murdock. Following his release from prison, Bont returned to a New York City vastly changed from the one he had once ruled. The traditional gangsters of his era had been replaced by costumed criminals with superpowers and theatrical personas. Enraged by this shift and seeking revenge against Daredevil—the hero responsible for his imprisonment—Bont resorted to the dangerously unstable Mutant Growth Hormone, which resulted in his death. A gender-swapped version of Alexander Bont, known as Alexandra, is portrayed by Sigourney Weaver in the 2017 miniseries The Defenders, a crossover of Marvel's Netflix series set within the Marvel Cinematic Universe (MCU). In the series, Alexandra is depicted as the leader of the Hand and one of its five "fingers".
AH receptor-interacting protein (AIP) also known as aryl hydrocarbon receptor-interacting protein, immunophilin homolog ARA9, or HBV X-associated protein 2 (XAP-2) is a protein that in humans is encoded by the AIP gene. The protein is a member of the FKBP family. AIP may play a positive role in aryl hydrocarbon receptor-mediated signalling possibly by influencing its receptivity for ligand and/or its nuclear targeting. AIP is the cellular negative regulator of the hepatitis B virus (HBV) X protein. Further, it's been known to suppress antiviral signaling and the induction of type I interferon by targeting IRF7, a key player in the antiviral signal pathways. AIP consists of an N-terminal FKBP52 like domain and a C-terminal TPR domain. AIP mutations may be the cause of a familial form of acromegaly, familial isolated pituitary adenoma (FIPA). Somatotropinomas (i.e. GH-producing pituitary adenomas), sometimes associated with prolactinomas, are present in most AIP mutated patients.
Sources: en.wikipedia.org
HPLC testing separates and quantifies components in a liquid sample. It is used to check identity, purity, concentration, or stability. The technique works best for compounds that dissolve and are not easily vaporized.
The pump maintains a steady flow rate and pressure, which keeps retention times reproducible. Pulsation or flow errors can shift peaks and distort quantitation. Modern pumps use feedback control to reduce these variations.
HPLC alone usually separates compounds but does not always identify them. Retention time matching with a known standard provides tentative identification. Coupling HPLC to mass spectrometry adds mass information that supports structural identification.
HPLC testing measures the presence and amount of one or more compounds in a liquid sample. It separates mixture components and records detector responses as peaks, which are compared with reference standards. Results are usually reported as concentrations or relative percentages.