A practical reference on quality control: what it is, how it behaves, what the literature reports, and where the honest uncertainties sit.
This page was last updated on 2026-06-13 and is reviewed periodically as new material appears.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
| Property | Value | Notes |
|---|---|---|
| Column particle size | 3–5 µm for conventional HPLC; sub-2 µm for UHPLC | Smaller particles increase backpressure and efficiency. |
| Typical flow rate | 0.5–2.0 mL/min for a 4.6 mm internal diameter column | Flow scales with column diameter and particle size. |
| UV detection wavelength | 190–400 nm | Selection depends on analyte chromophore. |
| Column temperature | 25–40 °C | Temperature affects retention, selectivity, and pressure. |
| Injection volume | 1–20 µL | Larger volumes may distort early-eluting peaks. |
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Because protein chains are open, AlphaKnot uses closure procedures before applying knot invariants. Its probabilistic method repeatedly closes the chain using randomly selected points on a large surrounding sphere and assigns the dominant topology obtained from the ensemble of closures. Deterministic alternatives connect the chain termini using prescribed geometries, including a direct closure and a closure constructed using the centre of mass. Knot identification uses the HOMFLY polynomial to distinguish knot types. AlphaKnot recognizes knots with minimal representations containing up to 12 crossings. In large-scale database calculations, structures that exhibit evidence of a nontrivial knot are subsequently analysed to determine the corresponding knot core, the smallest portion of the protein chain required to retain the detected topology. The database primarily reports the topology of the complete protein chain. More detailed information about subchain topologies can be obtained by calculating a knot map, which records the topology of different portions of the sequence. Because producing full knot maps for hundreds of thousands of structures would require substantial computational resources, these calculations are performed on demand rather than precomputed for the entire AlphaFold DB v4 dataset.
Alemtuzumab, sold under the brand names Campath and Lemtrada among others, is a medication used to treat chronic lymphocytic leukemia and multiple sclerosis. In chronic lymphocytic leukemia, it has been used as both a first line and second line treatment. It is given by injection into a vein. It is a monoclonal antibody that binds to CD52, a protein present on the surface of mature lymphocytes, but not on the stem cells from which these lymphocytes are derived. After treatment with alemtuzumab, these CD52-bearing lymphocytes are targeted for destruction. Alemtuzumab was approved for medical use in the United States in 2001. (Mab)Campath was withdrawn from the markets in the US and the EU in 2012, to prepare for a higher-priced relaunch of Lemtrada aimed at multiple sclerosis. Alemtuzumab is used for the treatment of B-cell chronic lymphocytic leukemia in people who have been treated with alkylating agents and who have failed fludarabine therapy. It is an unconjugated antibody, thought to work via the activation of antibody-dependent cell-mediated cytotoxicity.
Data from high-throughput chromosome conformation capture experiments, such as Hi-C (experiment) and ChIA-PET, can provide information on the three-dimensional structure and nuclear organization of chromatin. Bioinformatic challenges in this field include partitioning the genome into domains, such as Topologically Associating Domains (TADs), that are organised together in three-dimensional space. Finding the structure of proteins is an important application of bioinformatics. The Critical Assessment of Protein Structure Prediction (CASP) is an open competition where worldwide research groups submit protein models for evaluating unknown protein models.
Sources: en.wikipedia.org
RGD is the most widely used of a larger class of cell adhesive peptides. These short amino acid sequences are the minimum motif of a larger protein that is necessary for binding to a cell surface receptor that drives cell adhesion. The majority (89%) of published studies on biomaterials functionalized with cell adhesive peptides use RGD, whereas IKVAV and YIGSR are used in 6%, and 4% of those studies, respectively. Cell adhesive peptides isolated from fibronectin include RGD, RGDS, PHSRN, and REDV. YIGSR and IKVAV are isolated from laminin, whereas DGEA and GFOGER/GFPGER are isolated from collagen. Artificial amino acid sequences, which bear no biological similarity to ECM proteins, have also been synthesized, and include the α5β1-specific peptide RRETAWA.
Activity-based proteomics, or activity-based protein profiling (ABPP) is a chemoproteomic strategy that employs modular probes to directly assess the functional state of enzymes within complex proteomes. Unlike expression-based proteomics, which measures protein abundance, ABPP provides information about catalytic activity, thereby enabling researchers to distinguish between active and inactive forms of enzymes. This functional perspective has proven valuable for identifying drug targets, mapping ligandable sites, and understanding enzyme regulation in physiological and pathological contexts. By covalently modifying active sites, activity-based probes (ABPs) allow selective tagging, enrichment, and isolation of proteins, reducing the complexity of proteomic samples and facilitating downstream analysis. ABPP has been applied across diverse biological systems, including cells, tissues, and whole organisms, and has contributed to advances in biomarker discovery, drug development, and in vivo imaging.
14-3-3 proteins play an isoform-specific role in class switch recombination. They are believed to interact with the protein activation-induced cytidine deaminase in mediating class switch recombination. Phosphorylation of Cdc25C by CDS1 and CHEK1 creates a binding site for the 14-3-3 family of phosphoserine binding proteins. Binding of 14-3-3 has little effect on Cdc25C activity, and it is believed that 14-3-3 regulates Cdc25C by sequestering it to the cytoplasm, thereby preventing the interactions with CycB-Cdk1 that are localized to the nucleus at the G2/M transition. The eta isoform, YWHAH, is reported to be a biomarker (in synovial fluid) for rheumatoid arthritis. In a systematic review, 14-3-3η has been described as a welcome addition to the rheumatology field. The authors indicate that the serum based 14-3-3η marker is additive to the armamentarium of existing tools available to clinicians, and that there is adequate clinical evidence to support its clinical benefits in the management of patients diagnosed with rheumatoid arthritis (RA). 14-3-3 proteins bind to and sequester the transcriptional coregulators YAP/TAZ to the cytoplasm, inhibiting their function.
Camurus' FluidCrystal are available as injectable depots and topical bioadhesive delivery technologies. By encapsulating the drug compound in the nanostructures, injectable depots are able to deliver therapeutic levels of drug substance over extended periods from a single injection. This leads to a decrease in traditional side effects associated with high initial drug release on injection (drug burst), poor drug stability, and complex processing requirements, making the system highly suitable for sustained parental delivery of peptides, proteins, and small molecule drug compounds. The topical delivery system creates a bio-adhesive film that provides local and continual release of drug compounds. The delivery system is suited for delivery of peptide, protein, and small molecule drug compounds and can be applied to dermal, buccal, ophthalmic, nasal, vaginal, and other topical surfaces.
Sources: en.wikipedia.org
ACS Publications is the publishing division of the ACS. It is a nonprofit academic publisher of scientific journals covering various fields of chemistry and related sciences. As of 2026, ACS Publications published the following peer-reviewed journals: In addition to academic journals, ACS Publications also publishes Chemical & Engineering News, a weekly trade magazine covering news in the chemical profession, inChemistry, a magazine for undergraduate students, and ChemMatters, a magazine for high school students and teachers. ACS also created ChemRxiv, which is an open access preprint repository for the chemical sciences, co-owned, and collaboratively managed by the American Chemical Society (ACS), German Chemical Society (GDCh), Royal Society of Chemistry (RSC), the chemistry community, other societies, funders, and non-profits; open for submissions and available for all readers at ChemRxiv.
The citric acid cycle is regulated mainly by the availability of key substrates, particularly the ratio of NAD+ to NADH and the concentrations of calcium, inorganic phosphate, ATP, ADP, and AMP. Citrate – the ion that gives its name to the cycle – is a feedback inhibitor of citrate synthase and also inhibits PFK, providing a direct link between the regulation of the citric acid cycle and glycolysis.
Adenomatous polyposis coli protein 2 is a protein that in humans is encoded by the APC2 gene. This is a dual-functional protein which is especially prevalant in the developing brain, and involved in cell signaling (specifically Wnt signaling) and stabilizing the cytoskeleton. Frizzled receptors are a type of cell receptor involved in a variety of functions including embryonic development and cell proliferation. These receptors trigger a cascade of reactions called the Wnt signaling pathway that eventually leads to interaction with the DNA via the protein beta-catenin, which affects which proteins get produced by the cell. The APC2 protein promotes the formation of a protein complex which is involved in breaking down the protein beta-catenin. The APC2 protein stabilizes microtubules, which are part of the cell cytoskeleton. It may also be involved in the regulation of actin fibers my means of GTPase activation (specifically the Rho family).
In order for a protonated acid to lose a proton, the pH of the system must rise above the pKa of the acid. The decreased concentration of H+ in that basic solution shifts the equilibrium towards the conjugate base form (the deprotonated form of the acid). In lower-pH (more acidic) solutions, there is a high enough H+ concentration in the solution to cause the acid to remain in its protonated form. Solutions of weak acids and salts of their conjugate bases form buffer solutions. To determine the concentration of an acid in an aqueous solution, an acid–base titration is commonly performed. A strong base solution with a known concentration, usually NaOH or KOH, is added to neutralize the acid solution according to the color change of the indicator with the amount of base added. The titration curve of an acid titrated by a base has two axes, with the base volume on the x-axis and the solution's pH value on the y-axis. The pH of the solution always goes up as the base is added to the solution.
Discovered by Tillett and Francis in 1930, it was initially thought that CRP might be a pathogenic secretion since it was elevated in a variety of illnesses, including cancer. The later discovery of hepatic synthesis (made in the liver) demonstrated that it is a native protein. Initially, CRP was measured using the quellung reaction which gave a positive or a negative result. More precise methods nowadays use dynamic light scattering after reaction with CRP-specific antibodies. CRP was so named because it was first identified as a substance in the serum of patients with acute inflammation that reacted with the cell wall polysaccharide (C-polysaccharide) of pneumococcus.
Sources: en.wikipedia.org
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.
UHPLC uses columns with smaller particles and operates at higher pressures than conventional HPLC. These conditions can improve speed, resolution, and sensitivity. Both techniques use the same fundamental separation principles.
Validation shows that a method performs reliably for its intended purpose across a defined range. It assesses accuracy, precision, specificity, linearity, and robustness. Regulated testing often requires documented validation before routine use.
System suitability is typically performed before each batch or according to the validated method and laboratory procedure. Some long runs include periodic checks during analysis. The required frequency depends on regulatory expectations and method performance.