If you have been reading about retention time and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Last reviewed on 2025-10-27. Where a claim depends on a specific study, the study is described rather than over-claimed.
HPLC testing separates dissolved compounds by passing a liquid sample through a column packed with stationary phase. A pump delivers mobile phase at controlled flow, and the sample components interact differently with stationary and mobile phases. Compounds that spend more time in mobile phase elute earlier; those retained by stationary phase elute later. Detectors record elution as peaks, and peak area or height relates to amount. This mechanism underpins quantitative analysis of mixtures.
Most routine HPLC testing uses reversed-phase columns, where the stationary phase is nonpolar and the mobile phase is a polar mixture such as water with an organic solvent. Analytes partition between the two phases according to polarity, size, and charge. Gradients that change solvent composition over time can separate compounds with broad retention ranges. Isocratic conditions keep solvent composition constant and suit simpler mixtures. The choice of column chemistry, pH, and temperature affects selectivity and peak shape.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
| Property | Value | Notes |
|---|---|---|
| Separation mode | Reversed-phase | Nonpolar stationary phase with polar mobile phase |
| Typical column particle size | 3–5 µm | Smaller particles improve resolution but raise pressure |
| Typical flow rate | 0.5–2.0 mL/min | Depends on column dimensions and pressure limits |
| Common detection | UV-Vis absorbance | Requires analytes with chromophores |
| Typical run time | 5–30 min | Varies with method, gradient, and sample complexity |
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
Method validation establishes that an HPLC procedure is suitable for its intended use. Key parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Accuracy measures agreement with a true or accepted value, while precision describes repeatability and intermediate precision. Specificity confirms that the method measures the analyte without interference from impurities, degradants, or excipients. Validation is documented in a protocol and report, and acceptance criteria are set before experiments begin. Regulatory guidance varies by region, but the general principles are widely harmonized.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Common checks include retention time, peak area, resolution between critical pairs, tailing factor, and theoretical plate count. Results are compared with predefined limits, and a failed check requires investigation before sample results are reported. Quality control samples at low, middle, and high concentrations are injected at intervals to monitor accuracy and precision. Blank injections detect carryover and contamination, while control charts track performance over time.
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
From the 17th century, and before modern developments in organic chemistry nomenclature, acetone was given many different names. They included "spirit of Saturn", which was given when it was thought to be a compound of lead and, later, "pyro-acetic spirit" and "pyro-acetic ester". Prior to the name "acetone" being coined by French chemists, it was named "mesit" (from the Greek μεσίτης, meaning mediator) by Carl Reichenbach, who also said that methyl alcohol consisted of mesit and ethyl alcohol. Names derived from mesit include mesitylene and mesityl oxide which were first synthesised from acetone. In 1839, the name "acetone" began to be used, because it was obtained from acetic acid. Unlike many compounds with the acet- prefix which have a 2-carbon chain, acetone has a 3-carbon chain. That has caused confusion because there can not be a ketone with 2 carbons. The prefix refers to acetone's relation to vinegar (acetum in Latin, also the source of the words "acid" and "acetic"), rather than its chemical structure.
Alfred Zack Gilman (February 5, 1908 – January 13, 1984) was an American pharmacologist best known for pioneering early chemotherapy techniques using nitrogen mustard with his colleague, Louis S. Goodman. The pair also published the classic textbook The Pharmacological Basis of Therapeutics in 1941, and Gilman served as an editor for its first six editions. Gilman served on the faculties of the Yale School of Medicine, the Columbia College of Physicians and Surgeons, and the Albert Einstein College of Medicine, where he founded the Department of Pharmacology. He was a member of U.S. National Academy of Sciences.
The total nitrogen content of organic matter is mainly formed by the amino groups in proteins. The total Kjeldahl nitrogen (TKN) is a measure of nitrogen widely used in the analysis of (waste) water, soil, food, feed and organic matter in general. As the name suggests, the Kjeldahl method is applied. More sensitive methods are available. Media related to Amino acids at Wikimedia Commons
Sources: en.wikipedia.org
Arginylglycylaspartic acid (RGD) is the most common peptide motif responsible for cell adhesion to the extracellular matrix (ECM), found in species ranging from Drosophila to humans. Cell adhesion proteins called integrins recognize and bind to this sequence, which is found within many matrix proteins, including fibronectin, fibrinogen, vitronectin, osteopontin, and several other adhesive extracellular matrix proteins. The discovery of RGD and elucidation of how RGD binds to integrins has led to the development of a number of drugs and diagnostics, while the peptide itself is used ubiquitously in bioengineering. Depending on the application and the integrin targeted, RGD can be chemically modified or replaced by a similar peptide which promotes cell adhesion.
CPC Scientific’s manufacturing processes primarily use solid-phase peptide synthesis (SPPS), first described by Robert Bruce Merrifield in 1963. SPPS allows peptides to be assembled stepwise on a solid support, enabling the preparation of long and complex sequences for use as active pharmaceutical ingredients (APIs), investigational drugs, and research materials. Researchers associated with the company have published studies involving peptide synthesis methodologies, including work related to hydrocarbon stapling. Products manufactured by the company have been used and cited in various scientific studies. Official website
The vaginal environment is slightly acidic, with pH ranging from 3.8 - 4.5 based on multiple factors such as age, natural bacteria, and stage of menstrual cycle. Due to the variety in possible pH values, this poses an interesting consideration for drug delivery. Absorption and release of drugs is often influenced by pH, so if the pH is changing through the menstrual cycle, different combinations could be needed at different times to achieve the most effective drug delivery system.
People can also develop CJD because they carry a mutation of the gene that codes for the prion protein (PRNP), located on chromosome 202p12-pter. This occurs in only 10–15% of all CJD cases. In sporadic cases, the misfolding of the prion protein is a process that is hypothesized to occur as a result of the effects of aging on cellular machinery, explaining why the disease often appears later in life. An EU study determined that "87% of cases were sporadic, 8% genetic, 5% iatrogenic and less than 1% variant." Testing for CJD has historically been problematic, due to the nonspecific nature of early symptoms and difficulty in safely obtaining brain tissue for confirmation. The diagnosis may initially be suspected in a person with rapidly progressing dementia, particularly when it is also found with the characteristic medical signs and symptoms such as involuntary muscle jerking, difficulty with coordination/balance and walking, and visual disturbances. Further testing can support the diagnosis and may include:
Sources: en.wikipedia.org
It separates components in a liquid sample and measures their amounts using a detector. Results can indicate concentration, purity, or identity based on retention time and detector response. The technique works for mixtures that can be dissolved and filtered.
It offers high resolution, reproducibility, and compatibility with many sample types. A single run can separate and quantify multiple analytes. It is common in pharmaceutical, food, environmental, and industrial laboratories.
Samples must be soluble in a suitable mobile phase and free of particles that can block the column. Detector response depends on analyte structure, so some compounds need derivatization or alternative detection. Complex matrices may require extensive sample preparation.
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.