If you have been reading about accuracy and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Updated 2025-12-25. Numbers and descriptions here follow the published literature rather than marketing material.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
| Property | Value | Notes |
|---|---|---|
| Column particle size | 3–5 µm for conventional HPLC; sub-2 µm for UHPLC | Smaller particles increase backpressure and efficiency. |
| Typical flow rate | 0.5–2.0 mL/min for a 4.6 mm internal diameter column | Flow scales with column diameter and particle size. |
| UV detection wavelength | 190–400 nm | Selection depends on analyte chromophore. |
| Column temperature | 25–40 °C | Temperature affects retention, selectivity, and pressure. |
| Injection volume | 1–20 µL | Larger volumes may distort early-eluting peaks. |
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Pharmaceutical engineering is an interdisciplinary science that includes drug engineering, novel drug delivery and targeting, pharmaceutical technology, unit operations of chemical engineering, and pharmaceutical analysis. It may be deemed as a part of pharmacy due to its focus on the use of technology on chemical agents in providing better medicinal treatment. This is an extremely broad category—essentially covering all health care products that do not achieve their intended results through predominantly chemical (e.g., pharmaceuticals) or biological (e.g., vaccines) means, and do not involve metabolism. A medical device is intended for use in: the diagnosis of disease or other conditions in the cure, mitigation, treatment, or prevention of disease. Some examples include pacemakers, infusion pumps, the heart-lung machine, dialysis machines, artificial organs, implants, artificial limbs, corrective lenses, cochlear implants, ocular prosthetics, facial prosthetics, somato prosthetics, and dental implants.
Vaccine therapies are a type of specific active immunotherapy. Vaccine therapies deliver various agents that will lead to a specific immune response e.g. antibody development or CTL response. Tumor antigens have been a main target in specific active immunotherapy by way of vaccination. Tumor antigens are antigens produced by tumor cells and can be common among patients with the same cancer-type, or unique to a particular patient. Their specificity to malignant tumor cells makes tumor antigens ideal candidates for vaccination. Cancer vaccine C-Met#Active immunotherapy, Mantle cell lymphoma Immunotherapy,
Individual transmembrane adenylyl cyclase isoforms have been linked to numerous physiological functions. Soluble adenylyl cyclase (sAC, AC10) has a critical role in sperm motility. Adenylyl cyclase has been implicated in memory formation, functioning as a coincidence detector. AC-IV was first reported in the bacterium Aeromonas hydrophila, and the structure of the AC-IV from Yersinia pestis has been reported. These are the smallest of the AC enzyme classes; the AC-IV (CyaB) from Yersinia is a dimer of 19 kDa subunits with no known regulatory components (PDB: 2FJT). AC-IV forms a superfamily with mammalian thiamine-triphosphatase called CYTH (CyaB, thiamine triphosphatase). These forms of AC have been reported in specific bacteria (Prevotella ruminicola O68902 and Rhizobium etli Q8KY20, respectively) and have not been extensively characterized. There are a few extra members (~400 in Pfam) known to be in class VI. Class VI enzymes possess a catalytic core similar to the one in Class III.
Sources: en.wikipedia.org
Casokinins and lactokinins, breakdown products of casein and whey, occur naturally after ingestion of milk products, especially cultured milk. Their role in blood pressure control is uncertain. The lactotripeptides Val-Pro-Pro and Ile-Pro-Pro produced by the probiotic Lactobacillus helveticus or derived from casein have been shown to have ACE-inhibiting and antihypertensive functions. In one study, L. helveticus PR4 was isolated from Italian cheeses.
Gingras research focuses on the development of experimental and bioinformatics approaches for functional proteomics, with a focus on protein-protein and proximity interactions. She applies these tools to the study of signaling pathways in health and disease and in mapping the physical organization of the dynamic proteome. Some of her work focuses on the consequence of disease-associated mutations on the interactions established by proteins. In addition to proteomics, Gingras laboratory has interest in studying human protein phosphatase and their systematic interactions and has now expanded into the field of systems biology.
This is the largest division of the Society. It marked its 100th anniversary in 2008. The first Chair of the Division was Edward Curtis Franklin. The Organic Division played a part in establishing Organic Syntheses, Inc. and Organic Reactions, Inc. and it maintains close ties to both organizations. The Division's best known activities include organizing symposia (talks and poster sessions) at the biannual ACS National Meetings, for the purpose of recognizing promising Assistant Professors, talented young researchers, outstanding technical contributions from junior-level chemists, in the field of organic chemistry. The symposia also honor national award winners, including the Arthur C. Cope Award, Cope Scholar Award, James Flack Norris Award in Physical Organic Chemistry, Herbert C. Brown Award for Creative Research in Synthetic Methods. The Division helps to organize symposia at the international meeting called Pacifichem and it organizes the biennial National Organic Chemistry Symposium (NOS) which highlights recent advances in organic chemistry and hosts the Roger Adams Award address. The Division also organizes corporate sponsorships to provide fellowships for PhD students and undergraduates. It also organizes the Graduate Research Symposium and manages award and travel grant programs for undergraduates.
Sources: en.wikipedia.org
Apical dominance occurs when the shoot apex inhibits the growth of lateral buds so that the plant may grow vertically. It is important for the plant to devote energy to growing upward so that it can get more light to undergo photosynthesis. If the plant utilizes available energy for growing upward, it may be able to outcompete other individuals in the vicinity. Plants that were capable of outcompeting neighboring plants likely had higher fitness. Apical dominance is therefore most likely adaptive. Typically, the end of a shoot contains an apical bud, which is the location where shoot growth occurs. The apical bud produces a plant hormone, auxin (IAA), that inhibits growth of the lateral buds further down on the stem towards the axillary bud. Auxin is predominantly produced in the growing shoot apex and is transported throughout the plant via the phloem and diffuses into lateral buds which prevents elongation. That auxin likely regulates apical dominance was first discovered in 1934. When the apical bud is removed, the lowered IAA concentration allows the lateral buds to grow and produce new shoots, which compete to become the lead growth.
AAA proteins are divided into seven basic clades, based on secondary structure elements included within or near the core AAA fold: clamp loader, initiator, classic, superfamily III helicase, HCLR, H2-insert, and PS-II insert. AAA ATPases assemble into oligomeric assemblies (often homo-hexamers) that form a ring-shaped structure with a central pore. These proteins produce a molecular motor that couples ATP binding and hydrolysis to changes in conformational states that can be propagated through the assembly in order to act upon a target substrate, either translocating or remodelling the substrate. The central pore may be involved in substrate processing. In the hexameric configuration, the ATP-binding site is positioned at the interface between the subunits. Upon ATP binding and hydrolysis, AAA enzymes undergo conformational changes in the AAA-domains as well as in the N-domains. These motions can be transmitted to substrate protein.
Apamin is an 18 amino acid globular peptide neurotoxin found in apitoxin (bee venom). Dry bee venom consists of 2–3% of apamin. Apamin selectively blocks SK channels, a type of Ca2+-activated K+ channel expressed in the central nervous system. Toxicity is caused by only a few amino acids, in particular cysteine1, lysine4, arginine13, arginine14 and histidine18. These amino acids are involved in the binding of apamin to the Ca2+-activated K+ channel. Due to its specificity for SK channels, apamin is used as a drug in biomedical research to study the electrical properties of SK channels and their role in the afterhyperpolarizations occurring immediately following an action potential.
Sources: en.wikipedia.org
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.
UHPLC uses columns with smaller particles and operates at higher pressures than conventional HPLC. These conditions can improve speed, resolution, and sensitivity. Both techniques use the same fundamental separation principles.
Validation shows that a method performs reliably for its intended purpose across a defined range. It assesses accuracy, precision, specificity, linearity, and robustness. Regulated testing often requires documented validation before routine use.
It measures the presence and amount of one or more compounds in a liquid sample. Separation occurs in a column, and detection produces a signal proportional to concentration. Identification usually requires comparison with a known reference standard under the same conditions.