Everything below concerns Chromatogram. We keep the language plain, cite what the science says, and separate well-supported claims from open questions.
Last reviewed on 2026-04-18. Where a claim depends on a specific study, the study is described rather than over-claimed.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
3′,5′-cyclic AMP + diphosphate It has key regulatory roles in essentially all cells. It is the most polyphyletic known enzyme: six distinct classes have been described, all catalyzing the same reaction but representing unrelated gene families with no known sequence or structural homology. The best known class of adenylyl cyclases is class III or AC-III (Roman numerals are used for classes). AC-III occurs widely in eukaryotes and has important roles in many human tissues. All classes of adenylyl cyclase catalyse the conversion of adenosine triphosphate (ATP) to 3',5'-cyclic AMP (cAMP) and pyrophosphate. Magnesium ions are generally required and appear to be closely involved in the enzymatic mechanism. The cAMP produced by AC then serves as a regulatory signal via specific cAMP-binding proteins, either transcription factors, enzymes (e.g., cAMP-dependent kinases), or ion transporters.
Enzyme specificity refers to the interactions between any particular enzyme and its corresponding substrate. In addition to the specificity in binding its substrates, correct proximity and orientation as well as binding the transition state provide an additional layer of enzyme specificity. Enzymes vary in the specificity of the substrates that they bind to, in order to carry out specific physiological functions. Some enzymes may need to be less specific and therefore may bind to numerous substrates to catalyze a reaction. On the other hand, certain physiological functions require extreme specificity of the enzyme for a single specific substrate in order for a proper reaction and physiological phenotype to occur. The different types of categorizations differ based on their specificity for substrates. Most generally, they are divided into four groups: absolute, group, linkage, and stereochemical specificity.
The AlphaFold Protein Structure Database (AlphaFold DB) is a collaborative project with Google DeepMind to make predicted protein structures from the AlphaFold AI system freely available to the scientific community. The first release of the database was in 2021; as of 2024, AlphaFold DB provides access to over 214 million protein structures. National Center for Biotechnology Information (NCBI), United States National Library of Medicine National Institute of Genetics (DNA Data Bank of Japan) Swiss Institute of Bioinformatics (SIB: Expasy) Australia Bioinformatics Resource BIG Data Center (National Genomics Data Center), Beijing Institute of Genomics, Chinese Academy of Sciences Alternative splicing and transcript diversity database BioJS - open-source project for bioinformatics data on the web BioSamples European Molecular Biology Organization European Nucleotide Archive
Camurus AB (publ) is a Swedish research-based pharmaceutical and biotechnology company specialising in the commercialization of medicines for treating serious and chronic diseases. Established in 1991 and based in the southern university city of Lund, in the Medicon Valley region, the company is listed on Nasdaq Stockholm, Mid Cap. Camurus was founded by scientists in biophysical, food, and pharmaceutical chemistry with expertise in lipid phase structures. The company provides nanoscale drug-delivery systems for development of high-value therapeutics.
Sources: en.wikipedia.org
After synthesizing and purifying the core, the carbohydrate layer is added to its surface. Common coating materials are typically polyhydroxy oligomers such as cellobiose, citrate, lactose, and sucrose. This layer seems to be important for the properties of aquasomes, as it influences several drug characteristics including adsorption, molecular stability, and conformation (shape), and acts as a dehydroprotectant. The addition of the carbohydrate layer to the surface of the nanocrystalline core is commonly carried out by passive adsorption through incubation and sonication. Similar to the processing of the core, the carbohydrate layer is subjected to centrifugation, washing, and further sonification followed by heated air drying. Finally, the bioactive molecule of interest is loaded into the carbohydrate layer. This process typically occurs through either lyophilization or passive adsorption, and the fully functionalized aquasome is then characterized.
Adenylyl-sulfate reductase (glutathione) (EC 1.8.4.9) is an enzyme that catalyzes the chemical reaction AMP + sulfite + glutathione disulfide ⇌ {\displaystyle \rightleftharpoons } adenylyl sulfate + 2 glutathione The 3 substrates of this enzyme are adenosine monophosphate, sulfite, and glutathione disulfide, whereas its two products are adenylyl sulfate and glutathione. This enzyme belongs to the family of oxidoreductases, specifically those acting on a sulfur group of donors with a disulfide as acceptor. The systematic name of this enzyme class is AMP,sulfite:glutathione-disulfide oxidoreductase (adenosine-5'-phosphosulfate-forming). Other names in common use include 5'-adenylylsulfate reductase (also used for, internal_xref(ec_num(1,8,99,2))), AMP,sulfite:oxidized-glutathione oxidoreductase, (adenosine-5'-phosphosulfate-forming), and plant-type 5'-adenylylsulfate reductase. In plants, APS is reduced by the plastidic enzyme APS reductase (APR; EC 1.8.4.9) in the presence of physiological concentrations of reduced glutathione (GSH), which acts as an electron donor.
Acetylcysteine or N-acetylcysteine (NAC) is a mucolytic that is used to treat paracetamol (acetaminophen) overdose and to loosen thick mucus in individuals with chronic bronchopulmonary disorders, such as pneumonia and bronchitis. It has been used to treat lactobezoar in infants. It can be taken intravenously, orally (swallowed by mouth), or by inhalation by use of a nebulizer. It is also sometimes used as a dietary supplement. Common side effects include nausea and vomiting when taken orally. The skin may occasionally become red and itchy with any route of administration. A non-immune type of anaphylaxis may also occur. It appears to be safe in pregnancy. For paracetamol overdose, it works by increasing the level of glutathione, an antioxidant that can neutralize the toxic breakdown products of paracetamol. When inhaled, it acts as a mucolytic by decreasing the thickness of mucus. Acetylcysteine was initially patented in 1960 and came into medical use in 1968. It is on the World Health Organization's List of Essential Medicines. It is available as a generic medication.
C4H2N2O4 + GSH → C4H3N2O4• + GS• C4H3N2O4• + GSH → C4H4N2O4 + GS• C4H4N2O4 + O2 → C4H3N2O4• + O2•− + H+ C4H3N2O4• + O2 → C4H2N2O4 + O2•− + H+ Because it selectively kills the insulin-producing beta-cells found in the pancreas, alloxan is used to induce diabetes in laboratory animals. This occurs most likely because of selective uptake of the compound due to its structural similarity to glucose as well as the beta-cell's highly efficient uptake mechanism (GLUT2). In addition, alloxan has a high affinity to SH-containing cellular compounds and, as a result, reduces glutathione content. Furthermore, alloxan inhibits glucokinase, a SH-containing protein essential for insulin secretion induced by glucose. Most studies have shown that alloxan is not toxic to the human beta-cell, even in very high doses, probably because of differing glucose uptake mechanisms in humans and rodents. Alloxan is, however, toxic to the liver and the kidneys in high doses, as these are tissues where the GLUT2 transporter is expressed in humans. Streptozotocin
In pharmacology, relative bioavailability measures the bioavailability (estimated as the AUC) of a formulation (A) of a certain drug when compared with another formulation (B) of the same drug, usually an established standard, or through administration via a different route. When the standard consists of intravenously administered drug, this is known as absolute bioavailability (see above). F r e l = 100 ⋅ A U C A ⋅ D B A U C B ⋅ D A {\displaystyle F_{\mathrm {rel} }=100\cdot {\frac {AUC_{\mathrm {A} }\cdot D_{\mathrm {B} }}{AUC_{\mathrm {B} }\cdot D_{\mathrm {A} }}}}
Sources: en.wikipedia.org
AAA proteins are not restricted to eukaryotes. Prokaryotes have AAA which combine chaperone with proteolytic activity, for example in ClpAPS complex, which mediates protein degradation and recognition in E. coli. The basic recognition of proteins by AAAs is thought to occur through unfolded protein domains in the substrate protein. In HslU, a bacterial ClpX/ClpY homologue of the HSP100 family of AAA proteins, the N- and C-terminal subdomains move towards each other when nucleotides are bound and hydrolysed. The terminal domains are most distant in the nucleotide-free state and closest in the ADP-bound state. Thereby the opening of the central cavity is affected. AAA proteins are involved in protein degradation, membrane fusion, DNA replication, microtubule dynamics, intracellular transport, transcriptional activation, protein refolding, disassembly of protein complexes and protein aggregates.
Amivantamab, sold under the brand name Rybrevant, is a bispecific monoclonal antibody used to treat non-small cell lung cancer. Amivantamab is a bispecific epidermal growth factor (EGF) receptor-directed and MET receptor-directed antibody. It is the first treatment for adults with non-small cell lung cancer whose tumors have specific types of genetic mutations: epidermal growth factor receptor (EGFR) exon 20 insertion mutations. The most common side effects include rash, infusion-related reactions, skin infections around the fingernails or toenails, muscle and joint pain, shortness of breath, nausea, fatigue, swelling in the lower legs or hands or face, sores in the mouth, cough, constipation, vomiting and changes in certain blood tests. Amivantamab was approved for medical use in the United States in May 2021, and in the European Union in December 2021. The US Food and Drug Administration considers it to be a first-in-class medication.
Many different inventions and ideas which may or may not have been practical about auto safety have been put forward but never made it to a production car. Such items include the driver seat in the middle (to give the person a better view) (the exception being the McLaren F1 super car) and control stick steering. Automotive safety may have become an issue almost from the beginning of mechanised road vehicle development. The second steam-powered "Fardier" (artillery tractor), created by Nicolas-Joseph Cugnot in 1771, is reported by some to have crashed into a wall during its demonstration run. However, according to Georges Ageon, the earliest mention of this occurrence dates from 1801 and it does not feature in contemporary accounts. One of the earliest recorded car-related fatalities was Mary Ward, on August 31, 1869, in Parsonstown, Ireland. In 1922, the Duesenburg Model A became the first car to have four-wheel hydraulic brakes.
In May 2023, the FDA approved the iLet Bionic Pancreas system for people with Type 1 diabetes of six years and older. The device uses a closed-loop system to deliver both insulin and glucagon in response to sensed blood glucose levels. The 4th generation iLet prototype, presented in 2017, is around the size of an iPhone, with a touchscreen interface. It contains two chambers for both insulin and glucagon, and the device is configurable for use with only one hormone, or both. A 440-patient study of type I diabetes ran in 2020 and 2021 using a device configuration that delivered only insulin in comparison to standard of care; device use led to better circulating glucose control (measured by continuous monitoring) and a reduction in glycated hemoglobin (versus no change for the standard of care group). However, the incidence of severe hypoglycemic events was more than 1.5 times higher among device users versus standard care patients. There are several non-commercial, non-FDA approved DIY options, using open source code, including OpenAPS, Loop, and/or AndroidAPS.
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
System suitability is typically performed before each batch or according to the validated method and laboratory procedure. Some long runs include periodic checks during analysis. The required frequency depends on regulatory expectations and method performance.