High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
Seven genes encode seven distinct 14-3-3 proteins in most mammals (See Human genes below) and 13–15 genes in many higher plants, though typically in fungi they are present only in pairs. Protists have at least one. Eukaryotes can tolerate the loss of a single 14-3-3 gene if multiple genes are expressed, but deletion of all 14-3-3s (as experimentally determined in yeast) results in death. 14-3-3 proteins are structurally similar to the Tetratrico Peptide Repeat (TPR) superfamily, which generally have 9 or 10 alpha helices, and usually form homo- and/or hetero-dimer interactions along their amino-termini helices. These proteins contain a number of known common modification domains, including regions for divalent cation interaction, phosphorylation & acetylation, and proteolytic cleavage, among others established and predicted. 14-3-3 binds to peptides. There are common recognition motifs for 14-3-3 proteins that contain a phosphorylated serine or threonine residue, although binding to non-phosphorylated ligands has also been reported. This interaction occurs along a so-called binding groove or cleft that is amphipathic in nature. To date, the crystal structures of six classes of these proteins have been resolved and deposited in the public domain.
Affimer proteins were developed initially at the MRC Cancer Cell Unit in Cambridge then across two laboratories at the University of Leeds. Derived from the cysteine protease inhibitor family of cystatins, which function in nature as cysteine protease inhibitors, these 12–14 kDa proteins share the common tertiary structure of an alpha-helix lying on top of an anti-parallel beta-sheet. Affimer proteins display two peptide loops that can all be randomized to bind to desired target proteins, in a similar manner to monoclonal antibodies. Stabilization of the two peptides by the protein scaffold constrains the possible conformations that the peptides can take. This increases the binding affinity and specificity compared to libraries of free peptides, though can limit the target repertoire of Affimers.
The Department works at the intersection of organic chemistry (chemistry of natural products, chemistry of macrocyclic compounds, chemistry of elementorganic compounds), supramolecular chemistry (solution and self-process chemistry) and molecular biology. The head of the Department is Professor Igor S. Antipin, a corresponding member of the Russian Academy of Science, Doctor of Chemistry. The Department conducts research in the following fields:
In Brazil, the Aeronautical Accidents Investigation and Prevention Center (CENIPA) was established under the auspices of the Aeronautical Accident Investigation and Prevention Center, a Military Organization of the Brazilian Air Force (FAB). The organization is responsible for the activities of aircraft accident prevention, and investigation of civil and military aviation occurrences. Formed in 1971, and in accordance with international standards, CENIPA represented a new philosophy: investigations are conducted with the sole purpose of promoting the "prevention of aeronautical accidents". In Canada, the Transportation Safety Board of Canada (TSB), is an independent agency responsible for the advancement of transportation safety through the investigation and reporting of accident and incident occurrences in all prevalent Canadian modes of transportation – marine, air, rail and pipeline. In China, the Civil Aviation Administration of China (CAAC) is solely responsible for all air investigations and safety inside the country after the split from the formal CAAC Airlines.
Sources: en.wikipedia.org
Blood sugar regulation is the process by which the level of blood sugar, the common name for glucose dissolved in blood plasma, is maintained by the body within a narrow range. This tight regulation is referred to as glucose homeostasis. Insulin, which lowers blood sugar, and glucagon, which raises it, are the most well known of the hormones involved, but more recent discoveries of other glucoregulatory hormones have expanded understanding of this process. The pancreas gland secretes two hormones that are primarily responsible for regulation of glucose levels in blood. Blood sugar levels are regulated by negative feedback in order to keep the body in balance. The levels of glucose in the blood are monitored by many tissues, but the cells in the pancreatic islets are among the most well understood and important. Granule docking is an important glucose-dependent step in human insulin secretion that does not work properly in type 2 diabetes.
RANKL is a member of the TNF superfamily of ligands. Through binding to the RANK receptor it activates various molecules, like NF-kappa B, MAPK, NFAT and PI3K52. The RANKL/RANK signaling pathway regulates osteoclastogenesis, as well as, the survival and activation of osteoclasts. Adenosine is very relevant in bone metabolism, as it plays a role in formation and activation of both osteoclasts and osteoblasts. Adenosine acts by binding to purinergic receptors and influencing adenylyl cyclase activity and the formation of cAMP and PKA 54. Adenosine may have opposite effects on bone metabolism, because while certain purinergic receptors stimulate adenylyl cyclase activity, others have the opposite effect. Under certain circumstances adenosine stimulates bone destruction and in other situations it promotes bone formation, depending on the purinergic receptor that is being activated.
Individual transmembrane adenylyl cyclase isoforms have been linked to numerous physiological functions. Soluble adenylyl cyclase (sAC, AC10) has a critical role in sperm motility. Adenylyl cyclase has been implicated in memory formation, functioning as a coincidence detector. AC-IV was first reported in the bacterium Aeromonas hydrophila, and the structure of the AC-IV from Yersinia pestis has been reported. These are the smallest of the AC enzyme classes; the AC-IV (CyaB) from Yersinia is a dimer of 19 kDa subunits with no known regulatory components (PDB: 2FJT). AC-IV forms a superfamily with mammalian thiamine-triphosphatase called CYTH (CyaB, thiamine triphosphatase). These forms of AC have been reported in specific bacteria (Prevotella ruminicola O68902 and Rhizobium etli Q8KY20, respectively) and have not been extensively characterized. There are a few extra members (~400 in Pfam) known to be in class VI. Class VI enzymes possess a catalytic core similar to the one in Class III.
Sources: en.wikipedia.org
Libraries of peptide aptamers have been used as "mutagens", in studies in which an investigator introduces a library that expresses different peptide aptamers into a cell population, selects for a desired phenotype, and identifies those aptamers that cause the phenotype. The investigator then uses those aptamers as baits, for example in yeast two-hybrid screens to identify the cellular proteins targeted by those aptamers. Such experiments identify particular proteins bound by the aptamers, and protein interactions that the aptamers disrupt, to cause the phenotype. In addition, peptide aptamers derivatized with appropriate functional moieties can cause specific post-translational modification of their target proteins, or change the subcellular localization of the targets.
Most commonly 2,5-diketopiperazines are generated by cyclisation of dipeptides. In addition to the many methods of peptide synthesis, the Ugi reaction can be applied. Dipeptides with an ester terminus spontaneously cyclize often. Racemization can be problematic. The Ugi reaction using an isonitrile, amino acid, aldehyde and amine, can produce a dipeptide in equally high yield and optical purity, to that formed by standard peptide couplings. Commonly, an isonitrile is chosen to give a labile terminal amide to enable cyclization. For example, the direct 2,5-DKP ring formation via such an activated leaving group using the stable, easily accessible and versatile convertible isonitrile 1-isocyano-2-(2,2-dimethoxyethyl)-benzene 4 gave a one-pot synthesis of N-substituted 2,5-diketopiperazine's 7.
Most commonly 2,5-diketopiperazines are generated by cyclisation of dipeptides. In addition to the many methods of peptide synthesis, the Ugi reaction can be applied. Dipeptides with an ester terminus spontaneously cyclize often. Racemization can be problematic. The Ugi reaction using an isonitrile, amino acid, aldehyde and amine, can produce a dipeptide in equally high yield and optical purity, to that formed by standard peptide couplings. Commonly, an isonitrile is chosen to give a labile terminal amide to enable cyclization. For example, the direct 2,5-DKP ring formation via such an activated leaving group using the stable, easily accessible and versatile convertible isonitrile 1-isocyano-2-(2,2-dimethoxyethyl)-benzene 4 gave a one-pot synthesis of N-substituted 2,5-diketopiperazine's 7.
POMC, ACTH and β-lipotropin are secreted from corticotropic cells in the anterior lobe (or adenohypophysis) of the pituitary gland in response to the hormone corticotropin-releasing hormone (CRH) released by the hypothalamus. The pre-pro-opiomelanocortin (Pre-POMC) is the precursor of POMC, its cleavage forms POMC. ACTH, on the other hand, is produced from the cleavage of POMC. The removal of the signal peptide during translation produces the 241-amino acid polypeptide POMC, which undergoes a series of post-translational modifications such as phosphorylation and glycosylation before it is proteolytically cleaved by endopeptidases to yield various polypeptide fragments with varying physiological activity. These fragments include:
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
Validation establishes suitability for a new method, while verification confirms that a method works in a specific laboratory. Verification is often used when a validated method is adopted with existing equipment and staff. Both rely on documented acceptance criteria.