Everything below concerns reference standard. We keep the language plain, cite what the science says, and separate well-supported claims from open questions.
Updated 2026-01-17. Numbers and descriptions here follow the published literature rather than marketing material.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
| Property | Value | Notes |
|---|---|---|
| Retention time RSD | ≤1% for five replicate injections | Typical criterion; method-specific limits apply. |
| Resolution | ≥1.5 between critical pair | Baseline separation is generally desired. |
| Tailing factor | ≤2.0 | Measures peak symmetry. |
| Theoretical plates | ≥2000 per column | Method-dependent; higher values indicate greater efficiency. |
| Peak area RSD | ≤2% for replicate injections | Reflects autosampler and detector precision. |
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Quality control samples are inserted at intervals to monitor accuracy and precision throughout a batch. Blank samples detect contamination, while spiked samples assess recovery from the sample matrix. Calibration standards establish the relationship between detector response and concentration, and control samples are prepared independently from them whenever possible. Laboratories also participate in proficiency testing and maintain audit trails, instrument logs, and reagent records. Ongoing review of control charts can reveal trends before they cause out-of-specification results.
Method validation demonstrates that an HPLC procedure is suitable for its intended purpose. Common validation parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantification, and robustness. Accuracy reflects agreement with a reference value, while precision describes repeatability under defined conditions. Specificity shows whether the method can measure the analyte in the presence of impurities or matrix components. Validation documents are reviewed before a method is used for routine testing or regulatory submissions.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Typical checks include retention time, peak area precision, resolution between critical pairs, tailing factor, and theoretical plate count. Acceptance criteria are set in the method or pharmacopeial monograph. If a suitability check fails, the run may be rejected and the instrument or sample preparation may need investigation. This practice helps prevent release of data from a system that has drifted out of control.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Common checks include retention time, peak area, resolution between critical pairs, tailing factor, and theoretical plate count. Results are compared with predefined limits, and a failed check requires investigation before sample results are reported. Quality control samples at low, middle, and high concentrations are injected at intervals to monitor accuracy and precision. Blank injections detect carryover and contamination, while control charts track performance over time.
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
Method validation establishes that an HPLC procedure is suitable for its intended use. Key parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Accuracy measures agreement with a true or accepted value, while precision describes repeatability and intermediate precision. Specificity confirms that the method measures the analyte without interference from impurities, degradants, or excipients. Validation is documented in a protocol and report, and acceptance criteria are set before experiments begin. Regulatory guidance varies by region, but the general principles are widely harmonized.
All CHO cell lines are deficient in proline synthesis. Also, CHO cells do not express the epidermal growth factor receptor (EGFR), which makes them ideal in the investigation of various EGFR mutations. Furthermore, Chinese hamster ovary cells are able to produce proteins with complex glycosylations, post-translational modifications (PTMs) similar to those produced in humans. They are easily growable in large-scale cultures and have great viability, which is why they are ideal for GMP protein production. Also, CHO cells are tolerant to variations in parameters, be it oxygen levels, pH-value, temperature or cell density. Having a very low chromosome number (2n=22) for a mammal, the Chinese hamster is also a good model for radiation cytogenetics and tissue culture. Being the first cell line to be used for recombinant pharmaceutical production, regulatory concerns were raised with respect to Endogenous Retroviral Sequences (ERS). CHO cells contain about 1000 of these sequences and some of them are able to direct the synthesis of Intracisternal A-type particles and C-type particles. Also, low expression of reverse transcriptase was observed. However the majority of ERS are defective (stop codons in all reading frames) and contain large deletions of a putative retroviral genome.
In molecular biology, and more importantly high-throughput DNA sequencing, a chimera is a single DNA sequence originating when multiple transcripts or DNA sequences get joined. Chimeras can be considered artifacts and be filtered out from the data during processing to prevent spurious inferences of biological variation. However, chimeras should not be confused with chimeric reads, which are generally used by structural variant callers to detect structural variation events and are not always an indication of the presence of a chimeric transcript or gene. In a different context, the deliberate creation of artificial chimeras can also be a useful tool in molecular biology. For example, in protein engineering, "chimeragenesis" (forming chimeras between proteins that are encoded by homologous cDNAs) is one of the "two major techniques used to manipulate cDNA sequences". For gene fusions that occur through natural processes, see chimeric genes and fusion genes.
Cryptic binding sites are the binding sites that are transiently formed in an apo form or that are induced by ligand binding. Considering the cryptic binding sites increases the size of the potentially "druggable" human proteome from ~40% to ~78% of disease-associated proteins. The binding sites have been investigated by: support vector machine applied to "CryptoSite" data set, Extension of "CryptoSite" data set, long timescale molecular dynamics simulation with Markov state model and with biophysical experiments, and cryptic-site index that is based on relative accessible surface area.
The Bergmann degradation makes use of the azide degradation described by the Curtius rearrangement. Curtius also attempted to degrade benzoylated amino acids; however, his method involved splitting the carbamate with strongly energetic treatment with acids, which lead to decomposition of the resultant aldehyde and acid amides. This convinced Bergmann that Curtius' azide degradation could be followed by treatment with benzyl alcohol (his carbobenzoxy method) to isolate the resultant amino acid aldehyde and residual peptide amide for sequencing purposes.
Sources: en.wikipedia.org
In pharmacology, relative bioavailability measures the bioavailability (estimated as the AUC) of a formulation (A) of a certain drug when compared with another formulation (B) of the same drug, usually an established standard, or through administration via a different route. When the standard consists of intravenously administered drug, this is known as absolute bioavailability (see above). F r e l = 100 ⋅ A U C A ⋅ D B A U C B ⋅ D A {\displaystyle F_{\mathrm {rel} }=100\cdot {\frac {AUC_{\mathrm {A} }\cdot D_{\mathrm {B} }}{AUC_{\mathrm {B} }\cdot D_{\mathrm {A} }}}}
Chondrocytes can be prepared by sequential enzymatic digestion of cartilage with Pronase and Collagenase and cultured in DMEM-F12 cell culture media. Transplantation of dedifferentiated chondrocytes often leads to the formation of fibrous tissue formation. Redifferentiation of dedifferentiated chondrocytes in the 3-D system (spheroid culture) restore morphological and functional properties. Carticel is a procedure for restoring articular knee cartilage with autologous chondrocyte implantation; it was the first cell therapy to be approved by the U.S. Food and Drug Administration, under accelerated approval in 1997. In Australia, Ortho-ACI, a suspension of cultured autologous chondrocytes, is indicated for use in the treatment of cartilage lesions associated with the knee, patella, and ankle. Chondronectin Endochondral ossification Intramembranous ossification List of human cell types derived from the germ layers List of distinct cell types in the adult human body Histology image: 03317loa – Histology Learning System at Boston University Stem cell information
A third, only marginally related concept was proposed in 1923 by Gilbert N. Lewis, which includes reactions with acid–base characteristics that do not involve a proton transfer. A Lewis acid is a species that accepts a pair of electrons from another species; in other words, it is an electron pair acceptor. Brønsted acid–base reactions are proton transfer reactions while Lewis acid–base reactions are electron pair transfers. Many Lewis acids are not Brønsted–Lowry acids. Contrast how the following reactions are described in terms of acid–base chemistry:
Founded in 1984, Bio-Synthesis, Inc. was known as OCS Laboratories and was one of the first companies providing commercially available synthetic oligonucleotides to the biomedical research community worldwide. It was the first producer of commercially available synthetic DNA and became a producer of synthetic peptides in 1985, and became the only company to provide both synthetic DNA and peptide under one roof. Also in 1985 the process, now known as PCR, was discovered by Mullis et al. A key activity for Bio-Synthesis was to synthesize large number of PCR primer thus assisting and solidifying the early adoption of this now common and crucial process in biology.
The right side of a positive-sensed AAV genome encodes overlapping sequences of three capsid proteins, VP1, VP2 and VP3, and two accessory proteins, MAAP & AAP, which start from one promoter, designated p40. The molecular weights of these proteins are 87, 72 and 62 kiloDaltons, respectively. The AAV capsid is composed of a mixture of VP1, VP2, and VP3 totaling 60 monomers arranged in icosahedral symmetry in a ratio of 1:1:10, with an empty mass of approximately 3.8 MDa. The crystal structure of the VP3 protein was determined by Xie, Bue, et al.
Sources: en.wikipedia.org
The main building of the Institute is located at the intersection of Kremlyovskaya and Lobachevskaya streets. This four-story building built in 1953 in the style of Soviet neoclassicism under the guidance of architect A.G. Bikchentaev. The building of the museum of Kazan chemical school is located in the campus of the main university building, built in the 1830s in a classical style under the guidance of architect M.P. Corinfskiy. In 2015 construction of a large laboratory building in the campus of Alexander Butlerov Institute of Chemistry was finished. The 7-storey building housed classrooms and laboratories of departments of Alexander Butlerov Institute of Chemistry, Institute of Geology and Petroleum Technologies, Institute of Physics. The building was constructed with the support of the President of Tatarstan R.N. Minnikhanov and PSC "TAIF".
Acceptance sampling procedures became common during World War II. Sampling plans, such as MIL-STD-105, were developed by Harold F. Dodge and others and became frequently used as standards. More recently, quality assurance broadened the scope beyond final inspection to include all aspects of manufacturing. Broader quality management systems include methodologies such as statistical process control, HACCP, six sigma, and ISO 9000. Some use of acceptance sampling still remains.
The diagnosis of MADD needs to be considered in patients who have exercise induced myalgia, cramps and sometimes weakness. A mildly elevated creatine kinase may also occur. Exclusion of other muscular diseases such as McArdle's Disease and carnitine cycle abnormalities should occur. MADD may be identified if there is a lack of ammonia rise after forearm exercise testing. The diagnosis may then be confirmed with genetic testing.
Ana María Muñoz Jauregui (born 1969, Lima) is a Peruvian pharmacist, biochemist and nutritionist. She has served as Rector and, since 2023, as the Vice Rector of research at San Ignacio de Loyola University (USIL). Muñoz has authored numerous publications and received national and international awards, such as silver, gold medals and semi-grand prize wins at the International KIWIE Award. Muñoz, was born in Lima, Peru. In 1996, she attended the National University of San Marcos (UNMSM), where she earned her pharmaceutical degree. While studying, she developed an interest in the field of nutrition. She earned a master's degree in biochemistry and nutrition, and earned a PhD in Pharmacy and Biochemistry from the National University of San Marcos (UNMSM) in 2006.
The ACS International Activities is the birthplace of the ACS International Center, an online resource for scientists and engineers looking to study abroad or explore an international career or internship. The site houses information on hundreds of scholarships and grants related to all levels of experience to promote scientific mobility of researchers and practitioners in STEM fields. The Society grants membership to undergraduates as student members provided they can pay the $25 yearly dues. Any university may start its own ACS Student Chapter and receive benefits of undergraduate participation in regional conferences and discounts on ACS publications. The American Chemical Society administers 64 national awards, medals and prizes based on scientific contributions at various career levels that promote achievement across the chemical sciences. The ACS national awards program began in 1922 with the establishment of the Priestley Medal, the highest award offered by the ACS, which is given for distinguished services to chemistry.
Sources: en.wikipedia.org
System suitability is typically performed before each batch or according to the validated method and laboratory procedure. Some long runs include periodic checks during analysis. The required frequency depends on regulatory expectations and method performance.
Retention time drift can result from changes in mobile phase composition, column temperature, pump flow, or column age. A gradual shift often points to column degradation. A sudden shift may indicate a leak, mixing error, or incorrect mobile phase.
Retention time alone cannot confirm identity because different compounds may elute at similar times. Coupling HPLC with mass spectrometry or comparing against authenticated standards increases confidence. Confirmation usually requires orthogonal data.
System suitability is a set of checks performed before and during an HPLC run to confirm that the instrument and method are working as expected. It may include retention time repeatability, resolution between peaks, peak symmetry, and signal intensity. Failing suitability criteria usually invalidates the run.